Important Information About A Generator Maintenance Checklist for Diesel Generators

A commercial generator (a.k.a. genset) takes decades, but only if it is properly maintained. Although generators has few moving parts, it includes sensitive components that want regular attention. Complete genset maintenance requires different measures to get performed on different schedules. If you need a schedule for practicing these measures, here’s a basic checklist for heavy duty diesel generators maintenance on the daily, monthly, semiannual, and annual basis.

Daily Measures

Diesel generators should get the following measures each day:

General inspection – Look into the genset for loose parts, indications of corrosion on parts, traces of carbon, and dirt develop.
Coolant heater check – Ensure the coolant heater is securely in place and inspect it for warning signs of wear.
Oil check – check the oil level and add oil as necessary.
Fuel check – look into the fuel level and add fuel as necessary.
Charge-air piping check – make sure the charge-air piping is connected securely on the radiator and inspect it for warning signs of wear.
Maintenance personnel commonly carry out the measures above. Generator technicians can also perform them as part of a scheduled service agreement.

Weekly Measures

Diesel generators should have the following measures every week:

Air cleaner check – Look into the air cleaner for debris and cleanse it as necessary.
Wall charger check – Check the float voltage reading on the 12v charger and adjust the voltage as necessary.
Fuel Filter Drain – Drain water from your bottom from the fuel filter housing.
Fuel Tank Drain – Drain the lake from your bottom in the fuel tank prior to the diesel fuel appears.
Many facilities have generator technicians perform the weekly measures on a generator maintenance checklist. If building maintenance personnel perform them, they need to have lessons in generator maintenance.

Monthly Measures

Diesel generators should have the subsequent measures performed monthly:

Coolant concentration check – Take a sample from the coolant which has a hydrometer and appearance its concentration by referring to the service manual in the manufacturer.
Drive belt tension check – Look into the belt for proper tension and inspect it for warning signs of wear.
Exhaust condensate drain – Drain the condensate through the condensate trap.
Battery check – Check the charge about the starting battery and look at the connections for looseness and corrosion.
Because the correct power coolant within an outdoor generator may be relying on climate, an electrical generator technician who specializes in emergency power equipment should perform the coolant concentration check.

Semiannual Measures

Diesel generators needs to have the subsequent measures performed with a semiannual basis:

Oil and filter change – Replace the oil and oil filter, no matter if the genset has been utilized in the non-simulated power outage.
Coolant filter change – Switch the coolant filter, no matter whether the genset has been used inside a non-simulated power outage.
Crankcase breather cleaning – Clean the crankcase breather in line with the service manual in the manufacturer.
Home air cleaner element change – Switch the air cleaners element, whatever the degree of debris accumulation.
Radiator hose check – Confirm the connection from the radiator hoses and inspect them for signs of wear.
Fuel filter change – Change the fuel filter, regardless of amount of sediment accumulation.
Generator technicians should carry out the measures above.

Annual Measures

The genset must have a complete annual cleaning of their air conditioning.

Conclusion

The measures above are expected to get a diesel generator to be excellent condition. With many them in a generator maintenance checklist, it is possible to prepare the generator with your facility for the next power outage.